Tests of a P-67 boiler for an 800 MW unit.

Autor: Vasilyev, V., Borisov, V., Petrov, V., Kardachov, A., Porozov, S., Grebenkov, P., Yanov, S., Nazarov, M., Maidanik, M.
Zdroj: Power Technology & Engineering; Dec2010, Vol. 44 Issue 4, p307-313, 7p
Abstrakt: The rebuilding of the P-67 boiler for an 800 MW unit at the Berezovskaya GRÉS, as well as changes in the thermal engineering characteristics of the coal from the Berezovskii-1 seam and its slagging properties, are described. The results of balance tests of the boiler and changes in the thermal efficiency of heating surfaces during 2006 - 2008, including after mechanical cleaning and modernization of the combined cleaning system, as well as with coal dust coarsening and loading of the lower burner layers and downward blast, are discussed. [ABSTRACT FROM AUTHOR]