Radiotracer Dilution Method for Mercury Inventory Study in Electrolytic Cells.

Autor: Sugiharto, Su'ud, Zaki, Kurniadi, Rizal, Waris, Abdul, Santoso, Sigit Budi, Abidin, Zainal, Santoso, Gatot Budi
Předmět:
Zdroj: AIP Conference Proceedings; 6/22/2010, Vol. 1244 Issue 1, p247-252, 6p, 2 Charts, 1 Graph
Abstrakt: Purpose of the experiment is to demonstrate feasibility the use of radiotracer to measure weight of mercury in electrolytic cells of soda industry. The weight of mercury in each cell of the plant is designed approximately 1700 kg. Radiotracer is prepared by mixing 203Hg radioactive mercury with 2400 g of inactive mercury in a bath. The respective precisely weighted mercury aliquots to be injected into the cells are prepared by pouring approximately 130 g of radioactive mercury taken from the bath into 13 standard vials, in accordance with the number of the cells tested. Four standard references prepared by further dilution of ±2 g active mercury taken from the bath to obtain the dilution factors range of 12,000 to 20,000 from which the calibration graph is constructed. The injection process is conducting by pouring the radioactive mercury from aliquots into the flowing mercury at the inlet side of the cell and allows them to mix thoroughly. It is assumed that the mass of the radiotracer injected into a closed system remains constant, at least during the period of the test. From this experiment it was observed that the mixing time is two days after injection of radioactive mercury. The inactive mercury in each electrolytic cell calculated by the radiotracer method is of the range 1351.529 kg to 1966.354 kg with maximum error (95% confidence) is 1.52 %. The accuracy of measurement of the present method is better than gravimetric one which accounts 4 % of error on average. [ABSTRACT FROM AUTHOR]
Databáze: Complementary Index