Abstrakt: |
Recent studies report surprisingly low rates of implantable cardioverter defibrillator (ICD) placement for primary prevention against sudden cardiac death among patients with heart failure and left ventricular systolic dysfunction. Reasons for the low rates of utilization are not well understood. The authors examined ICD implantation rates at a university-based tertiary care center and used multivariable analysis to identify independent factors associated with ICD utilization. The ICD implantation rate for 850 eligible patients was 70%. Forty-seven (18%) patients refused implantation; women were twice as likely to refuse compared to men (8% vs 4%, P=.013). Race was not associated with utilization. On multivariable analysis, independent predictors of implantation included having a heart failure specialist (odds ratio [OR], 8.13; P<.001) or general cardiologist (OR, 2.23; P=.13) managing care, age range 70 to 79 (OR, 0.55; P<.001) or 80 and older (OR, 0.26; P<.001), female sex (OR, 0.49; P<.001), QRS interval (OR, 1.016; P<.001), diastolic blood pressure (OR, 0.979; P=.011), cerebrovascular disease (OR, 0.44; P=.007), and dementia (OR, 0.13; P=.002). Our registry of patients with cardiomyopathy and heart failure reveals that high rates of utilization are possible. Factors closely associated with ICD utilization include type of physician coordinating care, age, and comorbidities. Congest Heart Fail. 2010;16:141–146. © 2010 Wiley Periodicals, Inc. [ABSTRACT FROM AUTHOR] |