Failure to remove true sentinel nodes can cause failure of the sentinel node biopsy technique: Evidence from antimony concentrations in false-negative sentinel nodes from melanoma patients.

Autor: Scolyer, Richard, Thompson, John, Li, Ling-Xi, Beavis, Alison, Dawson, Michael, Doble, Phillip, Ka, Vivian, Gregory McKinnon, J., Soper, Robyne, Uren, Roger, Shaw, Helen, Stretch, Jonathan, McCarthy, Stanley
Zdroj: Annals of Surgical Oncology: An Oncology Journal for Surgeons; Mar2004 Supplement, Vol. 11, p174S-178S, 1p
Abstrakt: We have recently found that antimony (originating from the technetium 99m antimony trisulfide colloid, used for preoperative lymphoscintigraphy) can be measured in tissue sections from archival paraffin blocks of sentinel nodes (SNs) by means of inductively coupled plasma mass spectrometry (ICP-MS) to confirm that removed nodes are ture SNs. We performed a retrospective analysis of antimony concentrations in all our false-negative (FN) SNs to determine whether errors in lymphadenectomy (i.e., failure to remove true SNs) may be a cause of FN SN biopsies (SNBs). Among 27 patients with an FN SNB, metastases were found on histopathologic review of the original slides or additional sections in 7 of 23 patients for which they were available; however, antimony concentrations were low in 5 of 20 presumptive SNs. Our results suggest that an FN SNB can occur because of failure to remove the true SN as well as histopathologic misdiagnosis. [ABSTRACT FROM AUTHOR]
Databáze: Complementary Index