Autor: |
Zaryankin, A., Zroichikov, N., Arianov, S., Paramonov, A., Fichoryak, O. |
Zdroj: |
Thermal Engineering; Nov2006, Vol. 53 Issue 11, p862-867, 6p |
Abstrakt: |
The problem of the provision of uniform steam distribution in the inlet section of the nozzle row of the first uncontrolled stage of a turbine with partial steam admission is considered. This is achieved by means of a special perforated screen located at the inlet to the nozzles. [ABSTRACT FROM AUTHOR] |