Autor: |
I-Chen Tsai, Tain Lee, Min-Chi Chen, Yun-Ching Fu, Sheng-Lin Jan, Chung-Chi Wang, Yen Chang |
Předmět: |
|
Zdroj: |
Pediatric Radiology; Aug2007, Vol. 37 Issue 8, p818-825, 8p, 4 Black and White Photographs, 3 Charts |
Abstrakt: |
Multidetector CT (MDCT) seems to be a promising tool for detection of neonatal coronary arteries, but whether the ECG-gated or non-ECG-gated technique should be used has not been established. To compare the detection rate and image quality of neonatal coronary arteries on MDCT using ECG-gated and non-ECG-gated techniques. Twelve neonates with complex congenital heart disease were included. The CT scan was acquired using an ECG-gated technique, and the most quiescent phase of the RR interval was selected to represent the ECG-gated images. The raw data were then reconstructed without the ECG signal to obtain non-ECG-gated images. The detection rate and image quality of nine coronary artery segments in the two sets of images were then compared. A two-tailed paired t test was used with P values <0.05 considered as statistically significant. In all coronary segments the ECG-gated technique had a better detection rate and produced images of better quality. The difference between the two techniques ranged from 25% in the left main coronary artery to 100% in the distal right coronary artery. For neonates referred for MDCT, if evaluation of coronary artery anatomy is important for the clinical management or surgical planning, the ECG-gated technique should be used because it can reliably detect the coronary arteries. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |