Determination of plasma volume in anaesthetized piglets using the carbon monoxide (CO) method.

Autor: Heltne, J. K., Farstad, M., Lund, T., Koller, M. E., Matre, K., Rynning, S. E., Husby, P.
Předmět:
Zdroj: Laboratory Animals; Jul2002, Vol. 36 Issue 3, p344-350, 7p
Abstrakt: Based on measurements of the circulating red blood cell volume (VRBC) in seven anaesthetized piglets using carbon monoxide (CO) as a label, plasma volume (PV) was calculated for each animal. The increase in carboxyhaemoglobin (COHb) concentration following administration of a known amount of CO into a closed circuit re-breathing system was determined by diode-array spectrophotometry. Simultaneously measured haematocrit (HCT) and haemoglobin (Hb) values were used for PV calculation. The PV values were compared with simultaneously measured PVs determined using the Evans blue technique. Mean values (SD) for PV were 1708.6 (287.3)ml and 1738.7 (412.4)ml with the CO method and the Evans blue technique, respectively. Comparison of PVs determined with the two techniques demonstrated good correlation (r = 0.995). The mean difference between PV measurements was -29.9 ml and the limits of agreement (mean difference ±2SD) were -289.1 ml and 229.3 ml. In conclusion, the CO method can be applied easily under general anaesthesia and controlled ventilation with a simple administration system. The agreement between the compared methods was satisfactory. Plasma volume determined with the CO method is safe, accurate and has no signs of major side effects. [ABSTRACT FROM AUTHOR]
Databáze: Complementary Index