Autor: |
Tie Wei, Rodney Schmidt, Patrick McMurtry |
Zdroj: |
Experiments in Fluids; May2005, Vol. 38 Issue 5, p695-699, 5p |
Abstrakt: |
Abstract A known difficulty with using the Clauser chart method to determine the friction velocity in wall bounded flows is that it assumes, a priori, a logarithmic law for the mean velocity profile. Using both experimental and DNS data in the literature, this note explicitly shows how friction velocities obtained using the Clauser chart method can potentially mask subtle Reynolds-number-dependent behavior. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|