Autor: |
Sabat, Wiesław, Klepacki, Dariusz, Kamuda, Kazimierz, Kuryło, Kazimierz, Jankowski-Mihułowicz, Piotr |
Zdroj: |
Electronics (2079-9292); Dec2024, Vol. 13 Issue 23, p4607, 22p |
Abstrakt: |
The method for estimating the immunity of an AC/DC converter built in a commercial LED lamp to a 1.2/50 µs (8/20 µs) surge has been presented in this paper. A lamp with a direct drive LED inverter was selected to present the methodology for determining the coefficient of immunity of the test object to a standardized type of surge. The choice of this configuration was important for the testing process and presentation of the methodology to estimate the immunity coefficient of the tested system. In this work, the methodology for determining the deterministic immunity factor of the model inverter to a normalized type of disturbance was presented. Considerations were carried out for a 1.2/50 µs (8/20 µs) surge in accordance with the recommendations of the EN 61000-4-5:2014 standard. This conventional surge is used in laboratory practice to test the immunity of electronic and electrical systems and devices to disturbances that can be generated in the power grid during switching processes, short circuits, and direct and indirect lightning. In the first stage of testing on test benches, the intensity of damage to the integral components of a model inverter was examined with increasing levels of disturbance. Statistical measures characterizing their impact resistance were determined for each of the elements tested. Knowing their values, the value of this coefficient was finally determined for the lamp selected for testing, and the mechanism of its damage was analyzed. [ABSTRACT FROM AUTHOR] |