Autor: |
Wang, Linmin, Liu, Tingting, Xiao, Liang, Zhang, Haiting, Wang, Cunchen, Zhang, Weixian, Zhang, Mao, Wang, Ying, Deng, Shengqun |
Předmět: |
|
Zdroj: |
Insects (2075-4450); Nov2024, Vol. 15 Issue 11, p898, 13p |
Abstrakt: |
Simple Summary: Our research delved into the potential of using the Varian Clinac 23EX linear accelerator, typically employed in X-ray cancer treatment, as an alternative radiation source for the sterile insect technique (SIT) in mosquito control. Through our investigation, we found that by adjusting the X-ray dosage to a specific threshold, the resulting sterilization effect rivaled that achieved by traditional γ-ray sources. For example, at a dose of 60 Gy of X-rays and 40 Gy of γ-rays, the egg hatch rate can even be as low as 0.3%, which can result in induced sterility (IS) of 99.6%. This breakthrough opens up a convenient avenue for researchers, granting them access to readily available radiotherapy equipment for SIT studies. By leveraging the existing infrastructure, such as radiotherapy facilities, researchers can expedite their SIT research endeavors, potentially revolutionizing mosquito control efforts. The integration of radiotherapy equipment into SIT studies promises to propel advancements in this field, facilitating faster progress and fostering eco-friendly approaches to insect population management. The sterile insect technique (SIT) stands as an eco-friendly approach for mosquito control, but it is impeded by the limited availability of γ-ray radiation source. This research sought to investigate a different radiation source—the Varian Clinac 23EX linear accelerator, which is frequently used for X-ray therapy in cancer treatment. Evaluation parameters including emergence rate, average survival time, induced sterility (IS), male mating competitiveness of irradiated males and fecundity (the number of eggs per female per batch), and the egg hatch rate of females mated with irradiated males were assessed to gauge the application potential of this cancer treatment equipment in the realm of the SIT. The results indicated that X-rays from radiation therapy equipment can effectively suppress the hatch rate of offspring mosquitoes without adversely affecting the emergence rate of irradiated males or the fecundity of females. In addition, at an X-ray dose of 60 Gy, the induced sterility in Ae. aegypti was comparable to the sterility induced by 40 Gy of γ-rays with both treatments resulting in 99.6% sterility. Interestingly, when a release ratio of 7:1 (irradiated males:unirradiated males) was used to competitively mate with females, the IS results resulted by 60 Gy X-rays and 40 Gy γ-rays were still at 70.3% and 73.7%, respectively. In conclusion, the results underscored the potential of the Varian Clinac 23EX linear accelerator as an X-ray source in SIT research. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|
Nepřihlášeným uživatelům se plný text nezobrazuje |
K zobrazení výsledku je třeba se přihlásit.
|