This study aims to design a prosthetic knee model that is characterized by its lightweight, small number of components, and low cost. This study included two main parts: the first part, selecting the material used in manufacturing the knee joint and testing it mechanically, and the biomechanics test to measure the load applied on the joint. The second part includes designing the joint using the Solid Work program and analyzing it numerically using the ANSYS software. The results showed that both materials that were selected are qualified to manufacture the joint from due they have good mechanical properties according to the test results and are suitable for this application, as the value of the yield stress for the material AL2024T3 = 350 MPa and steel 410 = 325 MPa, while the maximum von Mises stress is generated from the numerical analysis process when applied the boundary conditions = 104.46 MPa. The results also showed that the knee joint model was successful in terms of design and gave high reliability to bear the patient's weight and not fail mechanically [ABSTRACT FROM AUTHOR] |