A double-channel methane (CH4) sensor was developed using a dual-pass multipass cell (DP-MPC) and a novel method that combines averaging dual-channel concentration signals with optimized detector gain configuration. This DP-MPC features two input/output coupling holes, resulting in absorption path lengths of approximately 95.8 m and 35.8 m, respectively. By optimizing the photodetector gain configuration and averaging the dual-channel concentration signals, the detection performance of the sensor was further enhanced. Allan deviation analysis indicated that after optimizing the detector gain, the measurement precision after dual-channel averaging reaches 21 ppb with an integration time of 1 s at a concentration of 2 ppm CH4, which is approximately 1.4 times higher than the measurement precision of the long-path channel (31 ppb) and short-path channel (30 ppb). The time required to achieve a measurement precision of 21 ppb is 2.4 s for the long-path channel and 2.1 s for the short-path channel. The response speed of the dual-channel averaging is approximately 2 times that of any single channel. Meanwhile, the sensor demonstrated its stability and reliability through continuous outdoor atmospheric CH4 measurements. [ABSTRACT FROM AUTHOR] |