Therapeutic Drug Monitoring of Infliximab and Adalimumab through Concentration and Anti-Drug Antibodies Assessment; Comparison of Sanquin Diagnostics and Theradiag Assays.

Autor: Vroemen, Wim H. M., Agata, Shakira S., van Beers, Joyce J. B. C., Damoiseaux, Jan G. M. C.
Předmět:
Zdroj: Antibodies (2073-4468); Sep2024, Vol. 13 Issue 3, p73, 9p
Abstrakt: Background: Therapeutic drug monitoring of biological Tumor Necrosis Factor (TNF)-alpha inhibitors is of critical importance. In this study, the performance of practically advantageous chemiluminescent immunoassays of Theradiag, assessing Infliximab and Adalimumab serum concentrations and anti-drug antibodies (ADA) against these biologics, were compared to the Enzyme-Linked Immuno-Sorbent Assays (ELISAs) from Sanquin Diagnostics. Methods: Leftover serum samples (n = 80 for each parameter) from patients treated with Infliximab or Adalimumab were collected. Correlation and agreement analyses for serum concentration and ADAs, respectively, were performed. Both Theradiag ADA assays, an assay targeting both free and bound ADAs and an assay targeting solely free ADAs, were investigated and compared to the Sanquin Diagnostics ADA assay, targeting both free and bound ADAs. Results: Strong positive correlations were observed between the biologic concentration assessment of Infliximab (Spearman's Rho = 0.91) and Adalimumab (Spearman's Rho = 0.94). However, there appeared to be significant bias in the Theradiag assay when compared to Sanquin (Infliximab median (Confidence Interval (CI)) = 2.1 (1.7–2.6) µg/mL; Adalimumab median (CI) = 0.8 (0.5–0.9) µg/mL). Agreement analyses showed moderate to good agreement for the Theradiag and Sanquin Diagnostics ADA assays, when detecting both free and bound ADAs, for Infliximab (Cohen's k = 0.717) and Adalimumab (Cohen's k = 0.802). In contrast, the Theradiag ADA assay detecting solely free ADAs had zero to poor agreement for Infliximab (Cohen's k = 0.458) and Adalimumab (Cohen's k = 0.119), respectively. Conclusions: This study demonstrated strong correlations and good agreement between the Theradiag and Sanquin Diagnostics assays measuring Infliximab and Adalimumab serum concentrations and ADAs, both free and bound, against these biologics. Discordance analyses showed significantly decreased drug concentrations in the solely free assays, indicating that the combined detection of free and bound ADAs better aligns with drug levels. [ABSTRACT FROM AUTHOR]
Databáze: Complementary Index
Nepřihlášeným uživatelům se plný text nezobrazuje