Single institution series describing external ventricular drain (EVD) placement and short- and long-term complications related to placement accuracy.

Autor: Sharma, Nikhil, Head, Jeffery R., Mallela, Arka N., Shanahan, Regan M., Canton, Stephen P., Abou-Al-Shaar, Hussam, Kass, Nicolás Matheo, Steuer, Fritz, Cheng, Lucille, Raver, Michael, Andrews, Edward G.
Předmět:
Zdroj: Surgical Neurology International; 2024, Vol. 15, p1-7, 7p
Abstrakt: Background: The placement of an external ventricular drain (EVD) for the treatment of acute hydrocephalus is one of the most common life-saving procedures that neurosurgeons perform worldwide. There are many wellknown complications associated with EVD placement, including tract hemorrhages, intra-parenchymal and subdural hemorrhages, infection, and catheter misplacement. Given the variety of complications associated with EVD placement and the inconsistent findings on the relationship of accuracy to complications, the present study reviewed short- and long-term complications related to EVD placement at our institution. Methods: A retrospective review was conducted for all consecutive patients who underwent bedside EVD placement for any indication between December 2020 and December 2021. Collected variables included demographic information, etiology of disease state, pre-and post-operative head computed tomography measurements, and post-procedural metrics (immediate and delayed complications). Results: A total of 124 patients qualified for inclusion in our study. EVDs that were non-functioning/exchanged were not significantly related to age, accuracy, ventriculomegaly, sex, disposition, laterality, type of EVD used, intraventricular hemorrhage (IVH), etiology, or Kakarla Grade (KG) (all P > 0.17). The need for a second EVD was similarly not related to age, accuracy, ventriculomegaly, sex, disposition, location, laterality, type of EVD used, IVH, etiology, or KG (all P > 0.130). Patients who died, however, were significantly more likely to have a second contralateral EVD placed (18.2% vs. 4.9% P = 0.029). We also found that left-sided EVDs were significantly more likely to fail within seven days of placement (29.4% vs 13.3%, P = 0.037; relative risk (RR) 1.93, 95% confidence interval: 1.09-3.43), unrelated to age, sex, etiology, type of EVD, IVH, location of the procedure, or accuracy (all P > 0.07). This remained significant when using a binary logistic regression to control for ventriculomegaly, accuracy, mortality, age, sex, and etiology (P = 0.021, B = 3.43). Conclusion: In our cohort, although a clear relationship between inaccuracy and complication rates was not found, our data did demonstrate that left-sided EVDs were more likely to fail within the immediate postoperative time point, and patients who died were more likely to have a second, contralateral EVD placed. [ABSTRACT FROM AUTHOR]
Databáze: Complementary Index