Preliminary study of hot gas duct heat transfer experimental power reactor.

Autor: Sulistyo, F. Y., Bakhri, S., Rohanda, A., Siswantara, A. I.
Předmět:
Zdroj: AIP Conference Proceedings; 2024, Vol. 2860 Issue 1, p1-7, 7p
Abstrakt: Experimental power reactor (RDE) is a 10 MWe high temperature gas cooled reactor that is designed by BATAN. A preliminary heat transfer analysis of hot gas duct, an important part in the reactor, has been studied and the result was satisfying and could be reanalyzed to obtain the exact method to solve the heat transfer issue. The design is simplified to maintain the specific parameter that will be analyze. The parameter are temperature, pressure and mass flow. The result is compared to technical RDE data and the result show that the error is below than 5%. This result is enough to represent the actual data and can be used to be the further design. The insulation material also put some effect that maintain the hot gas temperature stable. [ABSTRACT FROM AUTHOR]
Databáze: Complementary Index