Autor: |
ALBOTA, Florin, SERBAN, Andreea, IONUZ, Erhan, VIRGOLICI, Marian, DONEA, Catalin, DOBRESCU, Ioana, MOISE, Ioan-Valentin |
Předmět: |
|
Zdroj: |
Revue Roumaine de Chimie; Mar2024, Issue 3/4, p223-232, 10p |
Abstrakt: |
Healthcare associated infections consist a major concern in South-East European countries. As hospital activities try to eliminate the possible risks of infections, the quality of the disinfectants used in surgical sites, microbiological laboratories and other aseptic places must be ensured by using a proper product. In this context, the PEROKLIN product produced by Klintensiv Ldt., Romania, was tested using ICP-MS technique at the IFIN-HH Chemical and Physical Test Laboratory in terms of determining the elemental concentrations of several elements of interest. A dedicated chemical protocol was developed for that purpose and the method was validated according to international guidelines. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|