Validating the safety of low-dose CTPA in pregnancy: results from the OPTICA (Optimised CT Pulmonary Angiography in Pregnancy) Study.

Autor: Gillespie, Ciara D., Yates, Andrew, Hughes, Mark, Ewins, Karl, McMahon, Gabriella, Hynes, John, Murphy, Mark C., Galligan, Marie, Vencken, Sebastian, Alih, Ekele, Varden, John, Donnelly, Jennifer, Bolster, Ferdia, Rowan, Michael, Foley, Shane, NíAinle, Fionnuala, MacMahon, Peter J.
Předmět:
Zdroj: European Radiology; Aug2024, Vol. 34 Issue 8, p4864-4873, 10p
Abstrakt: Background: Pulmonary embolism (PE) is a leading cause of pregnancy-related mortality. CT pulmonary angiogram (CTPA) is the first-line advanced imaging modality for suspected PE in pregnancy at institutes offering low-dose techniques; however, a protocol balancing safety with low dose remains undefined. The wide range of CTPA doses reported in pregnancy suggests a lack of confidence in implementing low-dose techniques in this group. Purpose: To define and validate the safety, radiation dose and image quality of a low-dose CTPA protocol optimised for pregnancy. Materials and methods: The OPTICA study is a prospective observational study. Pregnant study participants with suspected PE underwent the same CTPA protocol between May 2018 and February 2022. The primary outcome, CTPA safety, was judged by the reference standard; the 3-month incidence of venous thromboembolism (VTE) in study participants with a negative index CTPA. Secondary outcomes defined radiation dose and image quality. Absorbed breast, maternal effective and fetal doses were estimated by Monte-Carlo simulation on gestation-matched phantoms. Image quality was assessed by signal-to-noise and contrast-to-noise ratios and a Likert score for pulmonary arterial enhancement. Results: A total of 116 CTPAs were performed in 113 pregnant women of which 16 CTPAs were excluded. PE was diagnosed on 1 CTPA and out-ruled in 99. The incidence of recurrent symptomatic VTE was 0.0% (one-sided 95% CI, 2.66%) at follow-up. The mean absorbed breast dose was 2.9 ± 2.1mGy, uterine/fetal dose was 0.1 ± 0.2mGy and maternal effective dose was 1.4 ± 0.9mSv. Signal-to-noise ratio (SNR) was 11.9 ± 3.7. Contrast-to-noise ratio (CNR) was 10.4 ± 3.5. Conclusion: The OPTICA CTPA protocol safely excluded PE in pregnant women across all trimesters, with low fetal and maternal radiation. Clinical relevance: OPTICA (Optimised CT Pulmonary Angiography in Pregnancy) is the first prospective study to define the achievable radiation dose, image-quality and safety of a low-dose CT pulmonary angiogram protocol optimised for pregnancy (NCT04179487). It provides the current benchmark for safe and achievable CT pulmonary angiogram doses in the pregnant population. Key Points: • Despite the increased use of CT pulmonary angiogram in pregnancy, an optimised low-dose protocol has not been defined and reported doses in pregnancy continue to vary widely. • The OPTICA (Optimised CT Pulmonary Angiography in Pregnancy) study prospectively defines the achievable dose, image quality and safety of a low-dose CT pulmonary angiogram protocol using widely available technology. • OPTICA provides a benchmark for safe and achievable CT pulmonary angiogram doses in the pregnant population. [ABSTRACT FROM AUTHOR]
Databáze: Complementary Index