Determination of the dose rate from the pulse-height spectra of an airborne gamma-ray spectrometer based on an unmanned aerial vehicle.

Autor: Gavrilov, S. L., Pimenov, A. E., Shvedov, A. M., Aron, D. V., Dyakov, S. V.
Předmět:
Zdroj: Atomic Energy; Nov2023, Vol. 135 Issue 1/2, p74-80, 7p
Abstrakt: In the present study, data for converting the pulse-height spectra of an airborne gamma-ray spectrometer with a NaI (31 × 31 mm) detector to the dose rate values were obtained using the mathematical simulation. The results were tested using model tasks for determining pulse-height spectra at heights from 15 to 75 m. A point isotropic source of 60Co and the infinite contamination of the soil surface with 137Cs were considered as sources of gamma-radiation. The simulation was carried out using the Monte Carlo method. As a result, uncertainties of obtained conversion coefficients for dose rate estimations were evaluated. [ABSTRACT FROM AUTHOR]