Autor: |
Martínez-Moreno, B., Guilabert, L., Martínez, J. Martinez, Herrera, I., Rodriguez, M., Miralles, C., Irurzun, J., Aparicio, J. R. |
Předmět: |
|
Zdroj: |
Endoscopy; 2024 Supplement 2, Vol. 56, pS66-S66, 1p |
Abstrakt: |
This article explores the concordance between Endoscopic Ultrasound (EUS)-guided portal pressure gradient (PPG) and the hepatic venous pressure gradient (HVPG) measurement in patients with established or suspected portal hypertension. The study found that EUS-PPG using a 22-gauge FNA needle is a reliable and safe technique for measuring the portal pressure gradient in cirrhotic patients. The correlation between EUS-PPG and HVPG was very good, suggesting that EUS-PPG could potentially become a new gold standard for estimating portal pressure gradient. However, there were a few cases with significant discrepancies between the two techniques, with the MASLD aetiology being associated with a higher occurrence of discrepancies. [Extracted from the article] |
Databáze: |
Complementary Index |