Autor: |
Bai, Xiaoze, Li, Mingduo, Di, Zhigang, Dong, Weichao, Liang, Jing, Zhang, Jingxuan, Sun, Hexu |
Předmět: |
|
Zdroj: |
Energy Science & Engineering; Mar2024, Vol. 12 Issue 3, p577-595, 19p |
Abstrakt: |
Aiming at the shortcomings of feature extraction and fault identification in fault diagnosis of wind power converters, a novel method for open circuit fault diagnosis of wind power converters based on variational mode decomposition (VMD) energy entropy (EE) and time domain feature analysis (TDFA) is proposed. Primarily, the three‐phase output current at the grid side of the wind power converter is collected as the original signal, and the VMD is used to decompose the original signal into a series of intrinsic mode functions (IMF). To reduce noise interference as much as possible, the Pearson correlation coefficient between each mode component and the original signal under different fault states is analyzed, and the IMF component containing the major failure features is selected to calculate the energy entropy of each component; afterward, according to the Pearson correlation coefficient results, the modal components of the first layer are selected for time domain feature analysis; finally, the feature matrix that combines energy entropy and time domain feature analysis is inputted into the long short‐term memory neural network for training and fault identification. The simulation and experimental results show that the open circuit fault diagnosis method proposed in this paper has high accuracy and robustness. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |