Autor: |
Salem, Samer Abu, Marom, Gad, Shein, Gabriel Szydlo, Fishman, Yuri, Helou, Brigitte, Brodie, Ronit, Elazary, Ram, Pikarsky, Alon J., Mintz, Yoav |
Předmět: |
|
Zdroj: |
Surgical Endoscopy & Other Interventional Techniques; Mar2024, Vol. 38 Issue 3, p1180-1190, 11p |
Abstrakt: |
Background: Achalasia is a rare disorder of the esophagus characterized by motor dysfunction in the esophagus and relaxation failure of the lower esophageal sphincter (LES). Currently, surgical myotomy procedures are considered the standard of care. Robotic Heller's myotomy (RHM) with fundoplication has been gaining popularity due to documented advantages in the precision of myotomy as well as avoiding the potential reflux following per-oral endoscopic myotomy (POEM). To the best of our knowledge, RHM has thus far has been performed exclusively by the da Vinci surgical system. The new Hugo RAS™ system offers a unique modular design and an open console which offers better maneuverability and docking options. In this study, we present the first worldwide series of patients undergoing RHM using the new Hugo RAS™ platform. Our objective is to propose optimal operating configuration and setup to fully harness the advantages of the unique modular design of this system. Methods: Ten consecutive achalasia patients underwent Robotic Heller's myotomy (RHM) with the Hugo RAS™ system. We prospectively collected patient data, including demographics, comorbidities, ASA class, Eckardt scores, pre-operative manometric data, and EndoFlip parameters. Additionally, we recorded the docking and total operative times. Results: Between December 2022 and August 2023, 10 patients underwent RHM with the Hugo™ RAS system. Patients had a median age of 42.5 years, 60% were female, and mean BMI was 23.2. Fifty percent had achalasia type 2 and 50% type 1. The median pre-operative integrated relaxation pressure (IRP) was 24.9. Median docking time was 10 min and overall operative time was 129.5 min. All patients, except one with acute coronary syndrome, had an uneventful peri-operative course and were discharged on post-operative day 2. Conclusion: The Hugo™ RAS system is well designed for robotic Heller myotomy. The operative and clinical results are similar to the currently used robotic system; however, the modular design of the system has some differences. These translate to better docking angles and maneuverability as well as console surgeon's ergonomics. Further experience is needed to explore the advantages of the system's modular design and function. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|