Autor: |
Rüggeberg, Sabrina, Wanglin, Antje, Demirel, Özlem, Hack, Rüdiger, Niederhaus, Birgit, Bidlingmaier, Bernd, Blumrich, Matthias, Usener, Dirk |
Předmět: |
|
Zdroj: |
Animals (2076-2615); Sep2023, Vol. 13 Issue 18, p2953, 13p |
Abstrakt: |
Simple Summary: The recent United States Pharmacopeia general chapter <121> requires a non-quantitative bioidentity test either as a rabbit blood sugar assay or as an in vitro insulin cell-based assay using in-cell Western (ICW) technology for insulin batch release. However, for quantification during stability or comparability studies, the rabbit blood sugar test is still required using a minimum of 24 rabbits to obtain one result. Based on the 3R principle (replace, reduce, and refine), this study sought to qualify the in vitro ICW cell-based bioassay approach for quantifying insulin activity. A bridging study with different insulins and stress samples revealed a clear correlation between the in vitro and in vivo test results. The replacement of the animal-based assay with the quantitative in vitro ICW cell-based bioassay for batch quality control saved cost, reduced cycle times while obtaining more meaningful and reliable data, and, above all else, reduced the suffering of many rabbits. For the quantification of insulin activity, United States Pharmacopeia (USP) general chapter <121> continues to require the rabbit blood sugar test. For new insulin or insulin analogue compounds, those quantitative data are expected for stability or comparability studies. At Sanofi, many rabbits were used to fulfil the authority's requirements to obtain quantitative insulin bioactivity data until the in vivo test was replaced. In order to demonstrate comparability between the in vivo and in vitro test systems, this study was designed to demonstrate equivalency. The measurement of insulin lispro and insulin glargine drug substance and drug product batches, including stress samples (diluted or after temperature stress of 30 min at 80 °C), revealed a clear correlation between the in vitro and in vivo test results. The recovery of quantitative in vitro in-cell Western (ICW) results compared to the in vivo test results was within the predefined acceptance limits of 80% to 125%. Thus, the in vitro ICW cell-based bioassay leads to results that are equivalent to the rabbit blood sugar test per USP <121>, and it is highly suitable for insulin activity quantification. For future development compounds, the in vitro in-cell Western cell-based assay can replace the rabbit blood sugar test required by USP <121>. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|
Nepřihlášeným uživatelům se plný text nezobrazuje |
K zobrazení výsledku je třeba se přihlásit.
|