Autor: |
Vandenbulcke, F., Anzillotti, G., Ravasio, G., Malagoli, E., Conte, P., Balzarini, B., Kirienko, A., Kon, E. |
Předmět: |
|
Zdroj: |
Journal of Experimental Orthopaedics; 8/1/2023, Vol. 10 Issue 1, p1-7, 7p |
Abstrakt: |
Purpose: The aims of this study were to assess the complications associated with the use of an external fixator-assisted plate osteosynthesis technique to stabilize a femoral bone defect in a rabbit model and to evaluate if this technique could avoid the mispositioning and the displacement of the femoral fragments during the surgical procedure. Methods: A preliminary cadaveric animal study was conducted to develop a new technique of external fixator-assisted plating. Thirty rabbits underwent a surgical procedure consisting in the creation of a femoral bone defect and, subsequently an implantation of a bone substitute through the assistance of a temporary external fixator. The fixator's ability to maintain length and alignment during surgery was documented. All intraoperative complications were prospectively collected. Results: No complications related to the use of the temporary external fixator were reported. The technique successfully prevented mispositioning and dislocation during plating in all the rabbits. Conclusion: In a rabbit animal model, the use of an external fixator-assisted plate osteosynthesis technique appears to be feasible and effective in avoiding misposition and rotation of femoral fragments when performing osteotomy and plating to create a mid-diaphyseal femoral defect. [ABSTRACT FROM AUTHOR] |