Abstrakt: Objective: To evaluate the geometrical effects of double keyhole loop (DKHL) and T-loop and its forces and moments during en mass space closure using finite element method. Materials and Methods: A 3-dimensional finite element model of maxillary arch was created and stimulated for first premolar extraction case with 0.022 slot Roth prescription bracket. DKHL and T-loop arch wire were created using 19×25 stainless steel and was opened 1 mm for activation using 2 different methods. The study was divided into 2 groups based on the loop design, method of activation, and degree of Gable bend. The stress distribution, tooth displacement, and moment-force ratio were calculated. Result: The overall stress distribution was more or less uniform in all the groups. However, maximum von Mises stress was observed in the second premolar region for both the groups. There was greater torque and vertical control in the anterior segment and better anchorage control in posterior segment with increase in degree of Gable bend for both the loops activated using ligature tie. Moment-force ratio of 8-10 was achieved for both the loops. Conclusion: Therefore, DKHL was as efficient as T-loop in producing the desirable biomechanical properties during en mass space closure. [ABSTRACT FROM AUTHOR]