Autor: |
Guerrero, Jaime, Alcaide-Moreno, Antonio, González-Espinosa, Ana, Arévalo, Roberto, Tunkel, Lev, Storch de Gracia, María Dolores, García-Rosales, Eduardo |
Předmět: |
|
Zdroj: |
Energies (19961073); Jul2023, Vol. 16 Issue 13, p4840, 20p |
Abstrakt: |
This work proposes an innovative method for adjusting the natural gas from the grid to the consumer pipeline requirements in a full-scale pressure reduction station. The use of two counterflow vortex tubes instead of the traditional boiler to preheat the gas before throttling is demonstrated as a powerful alternative. Thus, a reduction of fossil fuel consumption is reached, which amounts to 7.1 % less CO 2 emitted. To ensure the optimal configuration, the vortex tube was thoroughly characterized in laboratory facilities using nitrogen as the working fluid. Various operating conditions were tested to determine the most efficient setup. Computational Fluid Dynamics (CFD) simulations were conducted with nitrogen to validate the behavior of the vortex tube. Subsequently, the working fluid was switched to methane to assess the performance differences between the two gases. Finally, the vortex tubes were deployed at a full-scale installation and tested under real consumption demand. The results obtained from this study offer promising insights into the practical implementation of the proposed method for adjusting the natural gas flow, highlighting its potential for reducing fossil fuel consumption and minimizing CO 2 emissions. Further improvements and refinements can be made based on these findings. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|
Nepřihlášeným uživatelům se plný text nezobrazuje |
K zobrazení výsledku je třeba se přihlásit.
|