Autor: |
Šlanhof, Jiří, Průcha, Aleš, Nečasová, Barbora, Boháček, Adam |
Předmět: |
|
Zdroj: |
Materials Proceedings; Jun2023, Vol. 15 Issue 1, p36, 9p |
Abstrakt: |
This paper deals with the issue of fastening sheet-metal components on the facades of contemporary buildings that are massively insulated with external thermal insulation composite systems. This research focused on facades with thin-layer acrylic plaster and sheet-metal components made of aluminium, copper and hot-dipped galvanized sheet metal. Two different test methods and test sample geometries were used to determine the most critical aspects for the studied application sectors. Surprisingly high tensile properties as well as shear stresses in the bonded joints were recorded for all the selected combinations. The presented results confirmed the assumed benefits for the construction industry and the future practical use of this technology in construction, although the durability of a bonded joint will always depend mainly on the quality of the bonded substrate. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|