Autor: |
Tai, Yihsin, Mertes, Ian B., Chappell, Jenise, Jeon, Carolyn H., Husain, Fatima T. |
Předmět: |
|
Zdroj: |
International Journal of Audiology; May2023, Vol. 62 Issue 5, p442-452, 11p, 3 Charts, 4 Graphs |
Abstrakt: |
To investigate the effect of tinnitus and/or hyperacusis on distortion product otoacoustic emission (DPOAE) measures in adults with normal hearing thresholds from 0.25 to 8 kHz, while accounting for extended high-frequency (EHF) thresholds. A behavioural study consisted of comprehensive audiological assessment, validated tinnitus and hyperacusis questionnaires, DPOAE amplitudes and input/output (I/O) functions. Data of 56 participants with normal hearing were included for the analysis. Participants were categorised into four groups: (1) without tinnitus or hyperacusis, (2) with tinnitus only, (3) with hyperacusis only, and (4) with both tinnitus and hyperacusis. The groups with tinnitus showed elevated EHF thresholds compared with those without tinnitus. DPOAE amplitudes were not significantly affected by tinnitus and/or hyperacusis status; however, they were significantly affected by EHF thresholds. Further, no appreciable differences in DPOAE I/O functions were found across groups. The reported non-significant differences in DPOAEs in individuals with tinnitus and/or hyperacusis do not support a peripheral mechanism or an interaction between peripheral and central mechanisms underlying tinnitus or hyperacusis. Our findings, however, suggest the need to assess basal cochlear function (e.g. EHF thresholds) for a better understanding of differences in DPOAE measures in tinnitus and/or hyperacusis. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|