Osteochondral Allografts for Large Oval Defects of the Medial Femoral Condyle: A Comparison of Single Lateral Versus Medial Femoral Condyle Oval Grafts Versus 2 Overlapping Circular Grafts.

Autor: Mologne, Timothy S., Bugbee, William D., Kaushal, Shankar, Locke, Conor S., Goulet, Robert W., Casden, Michael, Grant, John A.
Předmět:
Zdroj: American Journal of Sports Medicine; Feb2023, Vol. 51 Issue 2, p379-388, 10p
Abstrakt: Background: Studies have demonstrated the acceptability of using a contralateral nonorthotopic lateral femoral condyle (LFC) graft for a circular medial femoral condyle (MFC) osteochondral defect up to 20 to 25 mm in diameter. Larger oblong defects can now be managed using either overlapping circle grafts or a single oblong-shaped osteochondral allograft (OCA). Purpose: To determine if an oblong contralateral nonorthotopic LFC OCA can attain an acceptable surface contour match compared with an oblong ipsilateral MFC OCA or an overlapping circle technique for large oblong defects of the MFC. Study Design: Controlled laboratory study. Methods: A total of 120 fresh-frozen human femoral condyles were matched by tibial width into 30 groups of 4 condyles (1 recipient MFC, 3 donor condyles). The recipient MFC was initially imaged using nano–computed tomography (nano-CT). A 17 × 36–mm oblong defect was created in the recipient MFC. Overall, 3 donor groups were formed: MFC oblong, LFC nonorthotopic oblong, LFC or MFC overlapping circles. After each transplant, the recipient condyle underwent nano-CT and was digitally reconstructed, which was superimposed on the initial nano-CT scan of the native recipient condyle. Dragonfly 3D software was used to determine the root mean square (RMS) of both the surface height deviation and the circumferential step-off height deviation between the native and donor cartilage surfaces for each graft. Results: RMS surface height deviations were as follows: 0.59 mm for MFC oblong grafts, 0.58 mm for LFC oblong grafts, and 0.78 mm for overlapping circle grafts. The MFC and LFC oblong grafts had significantly less surface height deviation than the overlapping circle grafts (P =.004 and P =.002, respectively). RMS step-off height deviations were as follows: 0.68 mm for MFC oblong grafts, 0.70 mm for LFC oblong grafts, and 0.85 mm for overlapping circle grafts. The MFC and LFC oblong grafts had significantly less step-off height deviation than the overlapping circle grafts (P <.001 and P =.002, respectively). The majority of this difference was on the medial segment of the overlapping circle grafts. Conclusion: Oblong ipsilateral MFC OCAs and oblong contralateral nonorthotopic LFC OCAs produced a significantly better surface contour match to the native MFC than overlapping circle grafts for oblong defects 17 × 36 mm in size. Clinical Relevance: Size-matched contralateral nonorthotopic LFC grafts are acceptable for MFC defects, which may allow for a quicker match, earlier patient care, and less wastage of valuable donor tissue. [ABSTRACT FROM AUTHOR]
Databáze: Complementary Index