Heart & Vessels; Jan2023, Vol. 38 Issue 1, p90-95, 6p |
Abstrakt: |
Ablation index (AI)-guided ablation is useful for pulmonary vein isolation (PVI) and cavotricuspid isthmus (CTI) ablation. However, the impact of radiofrequency (RF) application power on CTI ablation with a fixed target AI remains unclear. One-hundred-thirty drug-refractory atrial fibrillation and/or atrial flutter patients who underwent AI-guided CTI ablation with or without PVI between July 2020 and August 2021 were randomly assigned to high-power (45 W) and moderate-power (35 W) groups. We performed CTI ablation with the same target AI value in both groups: 500 for the anterior 1/3 segments and 450 for the posterior 2/3 segments. In total, first-pass conduction block of the CTI was obtained in 111 patients (85.4%), with 7 patients (5.4%) showing CTI reconnection. The rate of first-pass conduction block was significantly higher in the 45 W group (61/65, 93.8%) than in the 35 W group (50/65, 76.9%, P = 0.01). CTI ablation and CTI fluoroscopy time were significantly shorter in the 45 W group than in the 35 W group (CTI ablation time: 192.3 ± 84.8 vs. 319.8 ± 171.4 s, P < 0.0001; CTI fluoroscopy time: 125.2 ± 122.4 vs. 171.2 ± 124.0 s, P = 0.039). Although there was no significant difference, steam pops were identified in two patients from the 45 W group at the anterior segment of the CTI. The 45 W ablation strategy was faster and provided a higher probability of first-pass conduction block than the 35 W ablation strategy for CTI ablation with a fixed AI target. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|