Autor: |
Wen, Weiping, Kalkan, Erol |
Předmět: |
|
Zdroj: |
Journal of Earthquake Engineering; Dec2022, Vol. 26 Issue 16, p8670-8687, 18p |
Abstrakt: |
The dynamic responses of an instrumented twenty-story steel-moment frame office building were identified with the data from mainshock (M 7.1) occurred on November 30, 2018 and its six aftershocks ranging from M4.2 to 5.7 in the Alaska-Aleutian subduction zone. The deconvolution-based seismic interferometry was used to identify the traveling waves and intrinsic-damping ratio in the building. The median shear-wave velocity is 179 m/s for the east-west (EW), 201 m/s for the north-south (NS), and 174 m/s for the torsional responses. The building's average intrinsic-damping ratio is estimated to be 4.4% and 3.7% for the EW and NS directions, respectively. [ABSTRACT FROM AUTHOR] |