Autor: |
Wang, Runshen, Ong, Dominic E. L., Zhou, Jialin, Liu, Siwei, Oh, Erwin |
Předmět: |
|
Zdroj: |
Geosciences (2076-3263); Aug2022, Vol. 12 Issue 8, p284-N.PAG, 19p |
Abstrakt: |
A bi-directional static load test (BDSLT) is one of the most effective methods for accurately estimating pile bearing capacity, in which the test pile is divided into two portions by activating the single-loading device welded along the pile shaft. BDSLT, thus, eliminates the safety concerns and space limitations imposed by the reaction system, as compared to conventional static load tests (kentledge). Based on this study's project requirements, two loading devices (supercells) were welded along the pile shaft to provide sufficient bearing capacity under the BDSLT, and an equivalent method was applied to interpret the measured load–settlement response. Since the sacrificial loading device welded along the pile shaft cannot be re-used, BDSLTs lead to increased construction costs; however, their capacity for rapid set-up in a limited space and reliable application for long piles are benefits that easily justify their use. Therefore, researchers must understand how BDSLTs perform, especially regarding double-loading devices. As informed by site investigation, this paper validates the conventional analytical solutions regarding test piles in preliminary designs, including Alpha and Beta and semi-empirical methods. In terms of a soil stiffness reduction model, modified closed-form analytical solutions based on Randolph's analytical method were applied to predict the load–settlement response. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |