Blocking Studies to Evaluate Receptor-Specific Radioligand Binding in the CAM Model by PET and MR Imaging.

Autor: Löffler, Jessica, Herrmann, Hendrik, Scheidhauer, Ellen, Wirth, Mareike, Wasserloos, Anne, Solbach, Christoph, Glatting, Gerhard, Beer, Ambros J., Rasche, Volker, Winter, Gordon
Předmět:
Zdroj: Cancers; Aug2022, Vol. 14 Issue 16, p3870, 15p
Abstrakt: Simple Summary: In the development of new targeted radiopharmaceuticals, it is mandatory to demonstrate their target-specific binding. Rodents are still primarily used for these experiments. With respect to the 3Rs principles, the demand for alternative methods to reduce the number of animal experiments is continuously increasing. In the present study, we investigated whether radiotracer uptake specificity can be evaluated by blocking studies in the CAM model. PET and MR imaging were used to visualize and quantify ligand accumulation. It was demonstrated that the CAM model could be used to evaluate the target-specific binding of a radiopharmaceutical. Due to intrinsic limitations of the CAM model, animal testing will still be required at more advanced stages of compound development. Still, the CAM model could significantly reduce the number of experiments through early compound pre-selection. Inhibition studies in small animals are the standard for evaluating the specificity of newly developed drugs, including radiopharmaceuticals. Recently, it has been reported that the tumor accumulation of radiotracers can be assessed in the chorioallantoic membrane (CAM) model with similar results to experiments in mice, such contributing to the 3Rs principles (reduction, replacement, and refinement). However, inhibition studies to prove receptor-specific binding have not yet been performed in the CAM model. Thus, in the present work, we analyzed the feasibility of inhibition studies in ovo by PET and MRI using the PSMA-specific ligand [18F]siPSMA-14 and the corresponding inhibitor 2-PMPA. A dose-dependent blockade of [18F]siPSMA-14 uptake was successfully demonstrated by pre-dosing with different inhibitor concentrations. Based on these data, we conclude that the CAM model is suitable for performing inhibition studies to detect receptor-specific binding. While in the later stages of development of novel radiopharmaceuticals, testing in rodents will still be necessary for biodistribution analysis, the CAM model is a promising alternative to mouse experiments in the early phases of compound evaluation. Thus, using the CAM model and PET and MR imaging for early pre-selection of promising radiolabeled compounds could significantly reduce the number of animal experiments. [ABSTRACT FROM AUTHOR]
Databáze: Complementary Index