Characterization Sludge from Drying Area and Sludge Drying Bed in Sludge Treatment Plant Surabaya City for Waste to Energy Approach.

Autor: Septiariva, Iva Yenis, Suryawan, I. Wayan Koko, Zahra, Nurulbaiti Listyendah, Putri, Yika Nabila Kharisma, Sarwono, Ariyanti, Qonitan, Fatimah Dinan, Jun Wei Lim
Předmět:
Zdroj: Journal of Ecological Engineering; 2022, Vol. 23 Issue 7, p268-275, 8p
Abstrakt: The Sludge Treatment Plant (STP) in Surabaya produces solid waste in the form of sludge. The STP in Surabaya provides for Solid Separation Chamber (SSC), equalization unit, Oxidation Ditch (OD), final clarifier, distribution unit, polishing pond, sludge Drying Area (DA), Sludge Drying Bed (SDB), and reservoirs. Sludge waste generation is usually collected in DA and SDB units. This sludge is usually reprocessed for the recycling process, one of which is the waste to energy conversion with a thermochemical process. The difference between these two units is that DA is the sludge from preliminary treatment, while SDB is the sludge from secondary treatment, usually producing microbial biomass. This study aimed to evaluate the sludge produced by the two processing units as solid fuel. The water content of the DA sample is lower because the DA unit has mechanical processing, which separates solids from water. The results of the proximate test resulted in a significant difference between the SDB and DA units. The caloric value, water, ash, and fixed carbon values are significant (<0.05), while the volatile values differ for DA and SBD units. This shows that different treatment is needed for each unit to be appropriately processed as fuel. [ABSTRACT FROM AUTHOR]
Databáze: Complementary Index