In Vivo Comparison of Micro-Balloon Interventions (MBI) Advantage: A Retrospective Cohort Study of DEB-TACE Versus b-TACE and of SIRT Versus b-SIRT.

Autor: Lucatelli, Pierleone, De Rubeis, Gianluca, Trobiani, Claudio, Ungania, Sara, Rocco, Bianca, De Gyurgyokai, Simone Zilahi, Masi, Marica, Pecorella, Irene, Cappelli, Federico, Lai, Quirino, Catalano, Carlo, Vallati, Giulio
Zdroj: CardioVascular & Interventional Radiology; Mar2022, Vol. 45 Issue 3, p306-314, 9p
Abstrakt: Purpose: The purpose of this study was to evaluate in vivo the role of the micro-balloon by comparing trans-arterial chemoembolization (DEB-TACE) and selective internal radiotherapy (SIRT) procedures performed with and without balloon micro-catheter (b-DEB-TACE and DEB-TACE/SIRT and b-SIRT) for the treatment of hepatocellular carcinoma (HCC). Methods: The impact of a balloon micro-catheter on trans-arterial loco-regional treatment was analyzed using non-enhanced post-procedural cone-beam CT (Ne-CBCT) by comparing the attenuation values in the embolized area and the surrounding liver tissue before and after DEB-TACE versus b-DEB-TACE and by comparing 2D/3D dosimetry in single-photon emission computed tomography after SIRT versus b-SIRT, and by comparing the histological count of the beads following orthotopic liver transplantation in the DEB-TACE versus b-DEB-TACE subgroup. Results: We treated 84 HCC patients using trans-arterial loco-regional therapy. Fifty-three patients (26 DEB-TACE and 27 b-DEB-TACE) were analyzed in the TACE group. Contrast, signal-to-noise ratio, and contrast-to-noise ratio were all significantly higher in b-DEB-TACE subgroup than DEB-TACE (182.33 HU [CI95% 160.3–273.5] vs. 124 HU [CI95% 80.6–163.6]; 8.3 [CI95% 5.7–10.1] vs. 4.5 [CI95% 3.7–6.0]; 6.9 [CI95% 4.3–7.8] vs. 3.1 [CI95% 2.2–5.0] p < 0.05). Thirty-one patients (24 SIRT and 7 b-SIRT) were analyzed in the SIRT group. 2D dosimetry profile evaluation showed an activity intensity peak significantly higher in the b-SIRT than in the SIRT subgroup (987.5 ± 393.8 vs. 567.7 ± 302.2, p = 0.005). Regarding 3D dose analysis, the mean dose administered to the treated lesions was significantly higher in the b-SIRT than in the SIRT group (151.6 Gy ± 53.2 vs. 100.1 Gy ± 43.4, p = 0.01). In histological explanted liver analysis, there was a trend for higher intra-tumoral localization of embolic microspheres for b-DEB-TACE in comparison with DEB-TACE. Conclusions: Due to the use of three different methods, the results of this study demonstrate in vivo, a better embolization profile of oncological intra-arterial interventions performed with balloon micro-catheter regardless of the embolic agent employed. [ABSTRACT FROM AUTHOR]
Databáze: Complementary Index