Autor: |
Zhou, Kaihua, Tao, Xingguang, Pan, Fugen, Luo, Congfeng, Yang, Huilin |
Předmět: |
|
Zdroj: |
Journal of Investigative Surgery; Feb 2022, Vol. 35 Issue 2, p459-466, 8p |
Abstrakt: |
To investigate the clinical effect of novel patient-specific 3D printing templates based on external fixation for pelvic screw insertion compared with the fluoro-navigation technique. We retrospectively studied 18 pelvic fracture patients from July 2017 to July 2018. For analysis, patients were divided into two groups: the template group (15 screws in 8 patients) and the fluoro-navigation group (22 screws in 10 patients). The screw insertion time, radiation exposure time, and accuracy of the screw insertion as evaluated by postoperative CT scans were analyzed. In the template group, the average screw insertion time (11.5 ± 2.3 min/screw) was significantly 50.6% less than that in the fluoro-navigation group (23.3 ± 3.1 min/screw; P < 0.05). The average time of X-ray exposure in the template group (11.5 ± 3.9 s/screw) was also significantly 39.8% less than in the fluoro-navigation group (19.1 ± 2.5 s/screw; P < 0.05). In the template group, the mean deviation distance and angle between the actual and planned screw position was 2.6 ± 0.2 mm and 2 ± 0.3°. The patient-specific template based on external fixation can guide the insertion of the pelvic screw accurately and safely while significantly reducing operation and radiation exposure time. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|
Nepřihlášeným uživatelům se plný text nezobrazuje |