Autor: |
Soranno, Danielle E., Kirkbride‐Romeo, Lara, Han, Daniel, Altmann, Christopher, Rodell, Christopher B. |
Zdroj: |
Journal of Biomedical Materials Research, Part A; Mar2022, Vol. 110 Issue 3, p652-658, 7p |
Abstrakt: |
The continued development of minimally invasive therapeutic implants, such as injectable hydrogels, necessitates the concurrent advancement of methods to best assess their biocompatibility via functional outcomes in vivo. Biomaterial implants have been studied to treat kidney disease; however, assessment of biocompatibility has been limited to biomarker and histological assessments. Techniques now exist to measure kidney function serially in vivo in murine studies via transcutaneous measurements of glomerular filtration rate (tGFR). In this study, adult male and female wild‐type BalbC mice underwent right unilateral nephrectomy. The remaining solitary left kidney was allowed 4 weeks to recover via compensatory hypertrophy, after which subcapsular injection of either saline or shear‐thinning hyaluronic acid hydrogel was performed. Serial tGFR measurements before and after treatment were used to assess the effect of hydrogel injection on kidney filtration. Urine and serum biomarkers of kidney function, and kidney histology were also quantified. Hydrogel injection did not affect kidney function, as assessed by tGFR. Results were in agreement with standard metrics of serum and urine biomarkers of injury as well as histological assessment of inflammation. The model developed provides a direct functional assessment of implant compatibility for the treatment of kidney disease and impact on kidney function. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|