Assessing the cone of economy in patients with spinal disease using only a force plate: an observational retrospective cohort study.

Autor: Haddas, Ram, Wood, Addison, Lieberman, Isador, Derman, Peter B.
Předmět:
Zdroj: European Spine Journal; Sep2021, Vol. 30 Issue 9, p2504-2513, 10p, 1 Color Photograph, 4 Charts, 1 Graph
Abstrakt: Study design: This is a retrospective cohort with multiple regression modeling. Objective: The aim is to develop a new method for estimating cone of economy (CoE) using a force plate rather than traditional motion capture. Background: Currently, most spinal deformity surgeons rely on static radiographic parameters for alignment, balance, and outcomes data alongside patient-reported outcome measures. The CoE, the stable region of upright posture, can be objectively measured to determine the efficiency and balance of the spine. Motion capture technology is currently used to collect data to calculate CoE, but this requires expensive and complex equipment, which is a barrier to widespread adoption and clinical use of CoE measurements. Force plates, which measure pressure, are less expensive and can be used in a clinical setting. Methods: Motion capture and a force plate were used to quantify the CoE of 473 subjects (423 spinal surgical candidates; 50 healthy controls; 271 females; age: 58.60 ± 15.27; height: 1.69 ± 0.13; weight: 81.07 ± 20.91), and a linear multiple regression model was used to predict CoE using force plate data in a human motion laboratory setting. Patients were required to stand erect with feet together and eyes open in their self-perceived balanced and natural position for a full minute while measures of sway and center of pressure (CoP) were recorded. Results: The CoP variable regression model successfully predicted CoE measurements. The variables that were used to predict vertical CoE were CoP coronal sway, CoP sagittal sway, and CoP total sway in several combinations. The coefficient of determination for the head total sway model indicated a 87.0% correlation (F(3,469) = 1044.14, p < 0.001). The coefficient of determination for the head sagittal sway model indicated a 69.2% correlation (F(3,469) = 351.70, p < 0.001). The coefficient of determination for the head coronal sway model indicated a 85.2% correlation (F(3,469) = 899.27, p < 0001). Conclusion: Cone of economy was estimated from force plate data using center of pressure with high correlation without the use of motion capture in healthy controls and a variety of spine patients. This could lower the entry burden for measurement of the CoE in patients, enabling widespread use. This would provide surgeons objective global balance data, along with Haddas' CoE classification system, that could assist with surgical decision-making and facilitate objective monitoring surgical outcomes. [ABSTRACT FROM AUTHOR]
Databáze: Complementary Index