Beam Diagnostics for the BNL Energy Recovery Linac Test Facility.

Autor: Cameron, Peter, Ben-Zvi, Ilan, Blaskiewicz, Michael, Brennan, Michael, Connolly, Roger, Dawson, William, Degen, Chris, DellaPenna, Al, Gassner, David, Kesselman, Martin, Kewish, Jorg, Litvinenko, Vladimir, Mead, Joseph, Oerter, Brian, Russo, Tom, Vetter, Kurt, Yakimenko, Vitaly
Předmět:
Zdroj: AIP Conference Proceedings; 2004, Vol. 732 Issue 1, p232-237, 6p
Abstrakt: An Energy Recovery Linac (ERL) test facility is presently under construction at BNL. The goals of this test facility are first to demonstrate stable intense CW electron beam with parameters typical for the RHIC e-cooling project (and potentially for eRHIC), second to test novel elements of the ERL (high current CW photo-cathode, superconducting RF cavity with HOM dampers, and feedback systems), and finally to test lattice dependence of stability criteria. Planned diagnostics include position monitors, loss monitors, transverse profile monitors (both optical and wires), scrapers/halo monitors, a high resolution differential current monitor, phase monitors, an energy spread monitor, and a fast transverse monitor (for beam break-up studies and the energy feedback system). We discuss diagnostics challenges that are unique to this project, and present preliminary system specifications. In addition, we include a brief discussion of the timing system. © 2004 American Institute of Physics [ABSTRACT FROM AUTHOR]