Ion Chambers for Monitoring the NuMI Neutrino Beam at Fermilab.

Autor: Indurthy, Dharmaraj, Keisler, Ryan, Kopp, Sacha, Mendoza, Steven, Proga, Marek, Pavlovich, Zarko, Zwaska, Robert, Harris, Deborah, Marchionni, Alberto, Morfin, Jorge, Erwin, Albert, Ping, Huicana, Velissaris, Christos, Naples, Donna, Northacker, Dave, McDonald, Jeff, Diwan, Milind, Viren, Brett
Předmět:
Zdroj: AIP Conference Proceedings; 2004, Vol. 732 Issue 1, p332-340, 9p
Abstrakt: The Neutrinos at the Main Injector (NuMI) beamline will deliver an intense muon neutrino beam by focusing a beam of mesons into a long evacuated decay volume. The beam must be steered with 1-mRad angular accuracy toward the Soudan Underground Laboratory in northern Minnesota. We have built 4 arrays of ionization chambers to monitor the neutrino beam direction and quality. The arrays are located at 4 stations downstream of the decay volume, and measure the remnant hadron beam and tertiary muons produced along with neutrinos in meson decays. We review how the monitors will be used to make beam quality measurements, and as well review chamber construction details, radiation damage testing, calibration, and test beam results. © 2004 American Institute of Physics [ABSTRACT FROM AUTHOR]
Databáze: Complementary Index