Autor: |
Bestuzheva, A. S., Anakhaev, K. K. |
Zdroj: |
Power Technology & Engineering; Jul2020, Vol. 54 Issue 2, p147-153, 7p |
Abstrakt: |
A behavior of the seepage flow through a uniform earth-fill dam constructed on a limited-depth permeable foundation and provided with a cut-off wall has been studied, and effective counter-seepage arrangements within the dam foundation were developed. The studies were conducted by using an electro-hydrodynamic analogy (EHDA) method for various cut-off wall design schemes, including impervious diaphragms, inverted filters, etc. Based on the obtained experimental data, advantages and disadvantages of various counter-seepage schemes were established, and engineering recommendations were developed to increase the seepage safety and performance reliability of earth-fill dams with cut-off walls formed on permeable foundations. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|