Autor: |
Billdal, Daniel C., While, Peter T., Selnæs, Kirsten M., Sunoqrot, Mohammed R. S., Langørgen, Sverre, Bertilsson, Helena, Bathen, Tone F., Elschot, Mattijs, Selnaes, Kirsten M |
Předmět: |
|
Zdroj: |
Journal of Magnetic Resonance Imaging; Jun2020, Vol. 51 Issue 6, p1900-1910, 11p |
Abstrakt: |
Background: Relative enhanced diffusivity (RED) is a potential biomarker for indirectly measuring perfusion in tissue using diffusion-weighted magnetic resonance imaging (MRI) with 3 b values.Purpose: To optimize the RED MRI protocol for the prostate, and to investigate its potential for prostate cancer (PCa) diagnosis.Study Type: Prospective.Population: Ten asymptomatic healthy volunteers and 35 patients with clinical suspicion of PCa.Sequence: 3T T2 - and diffusion-weighted MRI with b values: b = 0, 50, [100], 150, [200], 250, [300], 400, 800 s/mm2 (values in brackets were only used for patients).Assessment: Monte Carlo simulations were performed to assess noise sensitivity of RED as a function of intermediate b value. Volunteers were scanned 3 times to assess repeatability of RED. Patient data were used to investigate RED's potential for discriminating between biopsy-confirmed cancer and healthy tissue, and between true and false positive radiological findings.Statistical Tests: Within-subject coefficient of variation (WCV) to assess repeatability and receiver-operating characteristic curve analysis and logistic regression to assess diagnostic performance of RED.Results: The repeatability was acceptable (WCV = 0.2-0.3) for all intermediate b values tested, apart from b = 50 s/mm2 (WCV = 0.3-0.4). The simulated RED values agreed well with the experimental data, showing that an intermediate b value between 150-250 s/mm2 minimizes noise sensitivity in both peripheral zone (PZ) and transition zone (TZ). RED calculated with the b values 0, 150 and 800 s/mm2 was significantly higher in tumors than in healthy tissue in both PZ (P < 0.001, area under the curve [AUC] = 0.85) and PZ + TZ (P < 0.001, AUC = 0.84). RED was shown to aid apparent diffusion coefficient (ADC) in differentiating between false-positive findings and true-positive PCa in the PZ (AUC; RED = 0.71, ADC = 0.74, RED+ADC = 0.77).Data Conclusion: RED is a repeatable biomarker that may have value for prostate cancer diagnosis. An intermediate b value in the range of 150-250 s/mm2 minimizes the influence of noise and maximizes repeatability.Level Of Evidence: 2 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2020;51:1900-1910. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|