Matching a Double Forming Line to Explosive-Emission Diode.

Autor: Remnev, G. E., Pushkarev, A. I., Furman, É. G.
Předmět:
Zdroj: Technical Physics Letters; Jul2004, Vol. 30 Issue 7, p603-604, 2p
Abstrakt: The regime of operation of an explosive-emission diode is affected by a matching transformer between this diode and a double forming line of a high-current electron accelerator. Preliminary forced demagnetization of the transformer core makes the shape of the voltage pulse applied to the cathode close to the optimum, corresponding to a decrease in the resistance of the anode–cathode gap related to expansion of the explosive-emission plasma. In addition, matching of the double forming line to the explosive-emission diode significantly decreases the amplitude of parasitic prepulses and increases (to 90–92%) the fraction of energy supplied to the diode during the main current pulse. © 2004 MAIK “Nauka / Interperiodica”. [ABSTRACT FROM AUTHOR]