Design Modifications, Fabrication and Test of HFDB-03 Racetrack Magnet Wound with Pre-Reacted Nb3Sn Rutherford Cable.

Autor: Ambrosio, G., Andreev, N., Barzi, E., Bhashyam, S., Carcagno, R., Feher, S., Imbasciati, L., Lamm, M., Pischalnikov, Y., Tartaglia, M., Tompkins, J., Zlobin, A. V.
Předmět:
Zdroj: AIP Conference Proceedings; 2004, Vol. 710 Issue 1, p767-774, 8p
Abstrakt: A 10 T racetrack magnet (HFDB-03) wound with pre-reacted Nb3Sn Rutherford cable has been fabricated and tested at Fermilab. This magnet is the third one in a proof-of-principle series for the use of the React-and-Wind technology in common-coil dipole magnets for future accelerators. It consists of two flat racetrack coils (28 turns each) separated by 5 mm. The maximum field on the coil, at the short sample limit of 16530 A, is 10 tesla. The cable has 41 strands with 0.7 mm diameter and the minimum bend radius in the magnet ends is 90 mm. The predecessor of this magnet (HFDB-02) reached 78 % of the short sample limit at 7.7 T. The mechanical design was improved and the fabrication procedure was slightly modified in order to address possible causes of limitation. In this paper we present the mechanical design and analysis of HFDB-03, the modifications to the fabrication procedure and the test results. © 2004 American Institute of Physics [ABSTRACT FROM AUTHOR]
Databáze: Complementary Index