Autor: |
Sewell, David J, Turner, Richard, Field, Ray, Holmes, William, Pradhan, Rahul, Spencer, Christopher, Oliver, Stephen G, Slater, Nigel KH, Dikicioglu, Duygu |
Zdroj: |
Biotechnology & Bioengineering; Jun2019, Vol. 116 Issue 6, p1315-1325, 11p |
Abstrakt: |
Without a scale‐down model for perfusion, high resource demand makes cell line screening or process development challenging, therefore, potentially successful cell lines or perfusion processes are unrealized and their ability untapped. We present here the refunctioning of a high‐capacity microscale system that is typically used in fed‐batch process development to allow perfusion operation utilizing in situ gravity settling and automated sampling. In this low resource setting, which involved routine perturbations in mixing, pH and dissolved oxygen concentrations, the specific productivity and the maximum cell concentration were higher than 3.0 × 106 mg/cell/day and 7 × 10 7 cells/ml, respectively, across replicate microscale perfusion runs conducted at one vessel volume exchange per day. A comparative analysis was conducted at bench scale with vessels operated in perfusion mode utilizing a cell retention device. Neither specific productivity nor product quality indicated by product aggregation (6%) was significantly different across scales 19 days after inoculation, thus demonstrating this setup to be a suitable and reliable platform for evaluating the performance of cell lines and the effect of process parameters, relevant to perfusion mode of culturing. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|