Autor: |
Aoyagi, Hideki, Kudo, Togo, Shukui Wu, Sato, Kazumichi, Sasaki, Shigeki, Tanaka, Hitoshi, Ishikawa, Tetsuya, Kitamura, Hideo, Warwick, T. |
Předmět: |
|
Zdroj: |
AIP Conference Proceedings; 2004, Vol. 705 Issue 1, p593-596, 4p |
Abstrakt: |
We have developed a high-speed and simultaneous photon beam diagnostic system using optical cables at SPring-8. The system is composed of blade type X-ray beam position monitors (XBPM) in front ends, optical cables spread over the experimental hall and multi A/D converters at the photon beam diagnostic station. Analog data of the beam positions are transferred through the optical cables. The multi A/D converter allows us to browse and process the data from the main control room in real time. The features of the system are the wide band-width, the ability of full-time observation with XBPMs and the compatibility to the monitoring system of electron beam position monitors in the storage ring. The system has been routinely used for high-speed and simultaneous measurements of photon beam and electron beam. © 2004 American Institute of Physics [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |