Effect of heat bed temperature of 3D bioprinter to hardness and compressive strength of scaffold bovine hydroxyapatite.

Autor: Triyono, Joko, Pratama, Aditya, Sukanto, Heru, Nugroho, Yohanes, Wijayanta, Agung Tri, Nur, Wijayanta, Budiman
Předmět:
Zdroj: AIP Conference Proceedings; 2018, Vol. 1931 Issue 1, p1-1, 1p, 8 Color Photographs, 1 Diagram, 3 Charts, 2 Graphs
Abstrakt: This study aimed to investigate the effect of heat bed temperature of 3D bioprinter toward compressive strength and hardness bovine bone hydroxyapatite scaffold for bone filler applications. BHA-glycerin mixed with a ratio of 1:1, and keep it for 24 hours. After the homogenization process acquired, bio-Ink with shaped slurry will be used as a material for a 3D printer. The printing process with a temperature variation have performed by setting up heat bed temperature. After printing process was completed, the 3D scaffold was detained on the heat bed for 10 minutes before being picked up. The test results in this study had the lowest hardness value of 9.82±0.62 VHN and the highest number of 24.32±0.99 VHN. The compressive strength testing had the lowest value of 1.62±0.16 MPa with the highest number of 5.67±0.39 MPa. Pore observation using a scanning electron microscope. The result shows that the size of the pores were not much different, that was ±100-200 µm. This observation also indicated that the pore form was square pores. [ABSTRACT FROM AUTHOR]
Databáze: Complementary Index