Saturated Vapor Pressure of Hydrogen Fluoride in the Region of Low Temperatures.

Autor: Gubanov, S., Durnovtsev, M., Krainov, A.
Předmět:
Zdroj: Journal of Engineering Physics & Thermophysics; May2017, Vol. 90 Issue 3, p634-636, 3p
Abstrakt: The results of measuring the saturated vapor pressure of anhydrous hydrogen fluoride in the temperature interval 140-190 K are presented. The schematic diagram of a test rig, instrumentation, and the technique of measurements are described. [ABSTRACT FROM AUTHOR]