Tension hydrothorax induced by malposition of central venous catheter -A case report-.

Autor: Seunghee Ki, Myoung-hun Kim, Wonjin Lee, Hakmoo Cho
Předmět:
Zdroj: Anesthesia & Pain Medicine; Apr2017, Vol. 12 Issue 2, p151-154, 4p
Abstrakt: Central venous catheterization is a useful method for monitoring central venous pressure and maintaining volume status. However, it is associated with several complications, such as pneumothorax, hydrothorax, hemothorax, and air embolism. Here we describe a case of iatrogenic tension hydrothorax after rapid infusion of fluid into the pleural space, following the misplacement of an internal jugular vein catheter. Despite ultrasonographic guidance during insertion of the central venous catheter, we were not able to avoid malposition of the catheter. The patient went into hemodynamic compromise during surgery, necessitating chest tube drainage and a mechanical ventilator postoperatively. This case shows that central venous catheter insertion under ultrasonographic guidance does not guarantee proper positioning of the catheter. [ABSTRACT FROM AUTHOR]