Abstrakt: |
Objective: To explore the clinical significance of adjusting the ultra filtration and maintaining stable hemodynamics by using the BioZ.com noninvasive hemodynamic monitoring system. Methods: The 41 patients treated with maintenance hemodialysis (MHD) were randomly divided into two groups, the case group and the control group, of which all the patients were measured CO, SV, LCW, LCWI, MAP and altered the ultra filtration in the case group by the BioZ.com noninvasive hemodynamic monitoring system. Results: 1) Before dialysis, compared with the control group, the TFC of the case group was statistically significant difference (P > 0.05). At the end of the dialysis, the TFC of the the case groups reduced obviously than the control group. 2) Before dialysis, compared with the control group, the CO, SV, LCW, LCWI, MAP of the case group was not statistically significant difference (P > 0.05). At the end of the dialysis, the CO, SV, LCW, LCWI (both P < 0.05) of the the case groups dropped as not further as the control group, MAP increased higher (P < 0.05). 3) Compared with the control group, the rate of the adverse event of the case group reduced (P < 0.05). Conclusion: The BioZ.com noninvasive hemodynaminc monitoring system could be used to conduct adjusting the ultra filtration in order to maintain stable hemodynamics and improve heart function and decrease the advers events of the maintenance hemodialysis patients. [ABSTRACT FROM AUTHOR] |