Removal of arsenic from aqueous solutions using waste iron columns inoculated with iron bacteria.

Autor: Azhdarpoor, Abooalfazl, Nikmanesh, Roya, Samaei, Mohammad Reza
Předmět:
Zdroj: Environmental Technology; Oct2015, Vol. 36 Issue 20, p2525-2531, 7p
Abstrakt: Arsenic contamination of water resources is one of the serious risks threatening natural ecosystems and human health. This study investigates arsenic removal using a waste iron column with and without iron bacteria in continuous and batch phases. In batch experiments, the effects of pH, contact time, initial concentration of arsenic and adsorbent dose were investigated. Results indicated that the highest arsenate removal efficiency occurred at pH 7 (96.76%). On increasing the amount of waste iron from 0.25 to 1 g, the removal rate changed from about 42.37%–96.70%. The results of continuous experiments on the column containing waste iron showed that as the empty bed contact time increased from 5 to 60 min, the secondary arsenate concentration changed from 23 to 6 µg/l. In experiments involving a waste iron column with iron bacteria, an increase in residence time from 5 to 60 min decreased the secondary arsenate concentration from 14.97 to 4.86 µg/l. The results of this study showed that waste iron containing iron bacteria is a good adsorbent for removal of arsenic from contaminated water. [ABSTRACT FROM PUBLISHER]
Databáze: Complementary Index